RFID-U: One Inventory Terminal — Three Form Factors

v1.4 · Multi-Tenant PWA UHF EPC-Gen2 · HID Wedge · Camera Offline-first · Service Worker UA / EN / DA / DE / FR / RU
RFID-U: One Inventory Terminal — Three Form Factors

Technical breakdown of a PWA-based inventory system for stock, seals, and assets. Demonstrates how a single database, a single API, and a single codebase operate seamlessly across a workstation, smartphone, and tablet — with each form factor addressing a specific field task.

Form Factors
3
PC · Smartphone · Tablet
Installations
0
PWA via HTTPS link
Interface Languages
6
UA · EN · DA · DE · FR · RU
TCO Reduction
≈ 79 %
vs. dedicated rugged handhelds

What is RFID-U and what problem does it solve?

RFID-U v1.4 is a cross-platform PWA inventory terminal that covers the tracking of stock, fixed assets, equipment, and security seals across facilities of any infrastructure: offices, warehouses, construction sites, manufacturing, logistics, and field service. The product is not «just another rugged handheld client» — it is a web application that functions both as a standalone offline tool and as a corporate client connecting to an isolated company database.

The architecture relies on three technological tiers. The first is the Service Worker and browser cache, ensuring full functionality during internet outages.[5] The second is a local or network WebSocket bridge to hardware UHF RFID readers, as browsers lack direct access to raw TCP/LLRP.[6][4] The third is server-side isolation between companies and GS1 EPCIS 2.0 events for data transfer to accounting systems.[3] Authentication is handled via Google OAuth 2.0,[7] data is stored in Google Cloud under a DPA,[10] compliant with GDPR.[8]

On the air interface side, the system operates with passive UHF tags compliant with ISO/IEC 18000-63:2021 (Gen2 Type C) in the European 865–868 MHz spectrum under ETSI EN 302 208.[1][2] The reader bridge utilizes precise IEEE 1588 PTP time synchronization — otherwise, multi-portal networks lose slot stability and increase event duplication.[9]

Form Factors: One Code, One Database, Different Operating Modes

Below are four windows of the exact same application, opened at different screen widths. No native builds, no installation packages: the same database, the same API, the same interface, but each width renders its own layout. It is crucial for engineers to see this difference to select the right tool for each part of the job.

Workstation (PC) — Dispatcher Mode

The workplace of a warehouse manager, foreman, or dispatcher — on a large screen. This is where all operations that cannot be comfortably done on a phone are performed: importing stock databases from 1C/Excel (including Ctrl+V pasting entire tables), managing 500+ items without losing table context, final document verification, and report preparation. A 1080–1920 px screen displays 9 modules simultaneously, the «five asset card state flags» (s1–s5), and the full set of attributes. Primary accessories include a keyboard, mouse, and drag & drop capability for files into the import block.

Open full version: rfid-u.netlify.app →

Smartphone — Field Terminal Mode

An Android or iPhone in the hands of an inventory specialist — the most common form factor. The smartphone camera becomes a 1D/2D barcode and QR seal scanner, and the screen becomes a Geiger indicator for locating specific RFID tags by RSSI (dBm) and audio feedback. All data is cached locally via Service Worker, so inventory doesn't stop during LTE or Wi-Fi dropouts: events queue offline and sync to the server at the first opportunity. A 390–430 px smartphone screen ensures single-handed operation, even with gloves.

Open on smartphone: rfid-u.netlify.app →

Tablet (Landscape) — Audit Mode

A 10–11 inch tablet in landscape orientation is the perfect compromise for field work and shop floor operations. The wide screen accommodates an entire row of 10+ asset card attributes and allows presenting acceptance reports to clients without scrolling. Input methods include fingers, stylus, camera, or HID scanners via USB-C. Technically, it is the exact same PWA without installation and with the same offline cache.

Open in landscape layout: rfid-u.netlify.app →

Tablet (Portrait) — Briefing Mode

Portrait tablet orientation is convenient for morning briefings, reading long instructions, or working in narrow aisles between racks where a landscape tablet might hit the shelves. The interface reflows into two columns (or one long one), preserving all functionality.

Open in portrait layout: rfid-u.netlify.app →

Architecture: What Happens Between the Reader and the Database

Three architectural tiers are visible before the first scan. The Client Tier is the PWA application in the browser, rendering in three layouts (phone, tablet, PC) from the same codebase. The Bridge Tier is a WebSocket service (ws:// / wss://, defaulting to port 5084) on a local or network host, maintaining a persistent connection to the hardware UHF RFID reader via LLRP v1.1 and broadcasting events to the browser.[4][6] The Server Tier is a cloud database with per-company isolation and APIs, where normalized GS1 EPCIS 2.0 events and export requests to XLSX/CSV/JSON/Markdown are processed.[3]

Two engineering decisions distinguish RFID-U from a «simple web wrapper over a rugged handheld». First — server-side event binding to the conveyor encoder: every read is timestamped to the millisecond, otherwise high-speed conveyors generate 4–6% duplicates that must be dropped in middleware. Second — document locking at the database rule level, not just in the UI: after a report is finalized, DB rules physically prohibit UPDATE and DELETE operations for that protocol and its rows, making the audit trail immutable even if UI bypasses are attempted.

Offline Mode. The Service Worker caches the PWA bundle, reference data, and the operation queue. During network loss, the application continues to operate fully; the queue syncs automatically upon reconnection. All events in the cache are timestamped and, after synchronization, assume their rightful place in the company's shared history.

Comparative Matrix of Operating Modes

Criterion PC Smartphone Tablet
Screen Width 1080–1920 px 390–430 px 768–1024 px
Primary Scenario Import from 1C/Excel, finalize reports, analytics Field inventory, camera scanning, Geiger search Warehouse audits with walk-throughs, client presentations, briefings
Data Input Keyboard, mouse, drag & drop, Ctrl+V Camera, touch, HID scanner via Bluetooth Touch, stylus, camera, HID scanner via USB-C
Offline Operation Yes (Service Worker + IndexedDB) Yes, prioritized Yes
Key Advantage Multitasking, large tables, reporting Mobility, single-handed operation Compromise: wide screen + mobility

5-Year TCO and ROI

A comparison of two inventory approaches for a mid-sized facility (25 employees with scanning rights). Option A — a classic fleet of industrial rugged handhelds with dedicated software. Option B — RFID-U v1.4 on employees' existing devices, plus a few industrial handhelds for extreme conditions. All amounts are in EUR (€).

Cost Item (5 years) Option A: Dedicated Handhelds Option B: RFID-U PWA
Purchase 25 industrial handhelds (≈ 1 200 €/unit) 30 000 € —
5 industrial handhelds for extreme conditions — 6 000 €
10 UHF RFID bridges + antenna kit 8 000 € 4 000 €
Licenses / Subscription for 25 seats 400 €/seat × 25 × 5 years = 50 000 € 80 €/seat × 25 × 5 years = 10 000 €
Tech support and fleet maintenance 150 €/unit × 25 × 5 years = 18 750 € included in subscription = 0 €
Employee training 5 000 € 3 000 €
Total 5-Year TCO 111 750 € 23 000 €

Additional CAPEX is zero: RFID-U does not require purchasing a full fleet of rugged handhelds because the primary workload shifts to the smartphones and tablets employees already own. 5-year savings: 111 750 € − 23 000 € = 88 750 €, or 79.4% of Option A's TCO. Cash flow effect: the annual RFID-U subscription (2 000 €) is fully offset by eliminating the annual licenses for the dedicated handheld fleet (10 000 €), meaning the software portion pays for itself within the first 3 months.

Key Takeaway. The primary savings of RFID-U are not «cheaper software», but rather «no need to buy a dedicated fleet of handhelds for 25 people when 20 of them already have a smartphone or tablet». Industrial handhelds remain only where physically necessary (minus 30 °C frost, IP69K washdown, gloved operation) — and this radically changes the project's budget structure.

FAQ

Why PWA and not a native Android/iOS app?

Three reasons. First, PWA updates instantly across all devices — no waiting for App Store / Google Play moderation. Second, a single codebase for all three form factors without separate builds and distinct APIs. Third, the offline mode via Service Worker provides the same resilience to network dropouts as a native app, but without installation and without needing hardware access permissions — all system capabilities (camera, clipboard, HID scanner) are accessible directly from the browser.

Does the solution comply with GDPR? Where is the data stored?

Yes. Authentication is handled via Google OAuth 2.0, and data is stored in Google Cloud under standard Data Processing Addendum (DPA), with the cloud region agreed upon during commercial deployment. Each company receives an isolated database at the server authorization rule level: a request to another workspace physically returns an empty result — this is enforced at the rule level, not in the UI. Full local backup export in JSON/XLSX/CSV is available at any time.

What happens to data when internet is lost on-site?

Inventory continues in full. The Service Worker caches the PWA bundle, reference data, and operation queue. Scans, created documents, s1–s5 flags, and tamper marks are saved to the browser's local storage. Upon network restoration, the queue synchronizes automatically, each operation receives a server timestamp, and version conflicts are resolved by the «last record tied to original client» rule.

What is required to work with physical UHF RFID readers?

Since browsers do not work directly with the LLRP protocol, the reader connects through a lightweight WebSocket bridge on a local or network host (default port 5084; if a local LLRP daemon occupies this port, select another available one). The bridge maintains the LLRP connection to the reader and broadcasts events to the browser via ws:// or wss://. No plugins, no drivers on workstations — just network access to the bridge.

Author: Yurii Kasian, Principal RFID Engineer · RFID Ukraine · Updated: November 16, 2026

Related RFID Architecture Articles

Sources and Standards

  1. ISO/IEC 18000-63:2021 — Information technology — Radio frequency identification for item management — Part 63: Air interface communications at 860 MHz to 960 MHz Type C. ISO/IEC, 2021.
  2. ETSI EN 302 208 — Radio Frequency Identification Equipment operating in the band 865 MHz to 868 MHz with power levels up to 2 W ERP. ETSI, 2023.
  3. GS1 EPCIS 2.0 — EPC Information Services (EPCIS) Standard, Version 2.0. GS1, 2022.
  4. GS1 LLRP v1.1 — Low Level Reader Protocol Standard, Version 1.1. GS1, 2017.
  5. W3C Service Workers / PWA — Service Workers Working Draft; Web App Manifest specification. W3C, 2023.
  6. RFC 6455 — The WebSocket Protocol. IETF, 2011.
  7. RFC 6749 — The OAuth 2.0 Authorization Framework. IETF, 2012.
  8. GDPR (EU) 2016/679 — General Data Protection Regulation. EU, 2016.
  9. IEEE 1588-2019 (PTPv2.1) — IEEE Standard for a Precision Clock Synchronization Protocol for Networked Measurement and Control Systems. IEEE, 2019.
  10. Google Cloud Data Processing Addendum — Standard contractual terms for cloud data processing under GDPR. Google, 2024.

Ask a Question